PICC Line
Air Embolism
Air may enter the catheter if it becomes disconnected while unclamped. During inspiration, intra-thoracic pressure decreases relative to atmospheric pressure, thus facilitating travel of an air embolus from high pressure (atmosphere) to low pressure (intra-thoracic). Prevention is key!
- Ensure an injection cap is attached to each lumen of the central venous catheter
- Ensure all connections are securely luer-locked
- Clamp the catheter when opening the system
- Ensure that any air within the injection site cap/catheter has been withdrawn prior to injecting any fluid
- Never use scissors to remove the dressing
- If the line becomes disconnected, clamp proximal to the damage. Attach a 10mL syringe to remove air that may have entered the catheter
- The catheter may be repaired with a special kit specific for type and size of the long-term central venous catheter, which can be obtained from the OR.
- In case of an air embolus:
- Turn the patient to left lateral Trendelenburg position
- Administer oxygen